Install your own mini split, one figure at a time.

Plain how-to guides for homeowners anywhere in the US. Pick a part of the drawing to see what the job involves.

Exploded drawing of a single-zone mini split with six numbered parts inside outside 1 2 3 4 5 6
Fig. 1. A single-zone system pulled apart. Not to scale.

    Start here

    Six guides, in the order the job happens. Most people spread them over two weekends: one for planning and mounting, one for wiring, vacuum and startup.

    1. Size the system for your climate

      Work out how much heating and cooling the room needs before you look at a single product page.

      20 min read, no tools
    2. Choose the spots and hang the indoor unit

      Clearances, studs, a level plate, and a hole that slopes the right way.

      Half a day
    3. Run and connect the line set

      Gentle bends, clean flares, the right torque, and a tidy cover.

      3 to 4 hours
    4. Wire the disconnect and the units

      A dedicated circuit, an outdoor disconnect, and the cable between the two units. Know when to call an electrician.

      Half a day, permit likely
    5. Pressure test and pull a vacuum

      The step that decides how long the system lasts. Skipped only on sealed, pre-charged quick-connect lines.

      2 hours
    6. Release the charge and start it up

      Open the valves, check for leaks once more, and run both modes for twenty minutes each.

      1 hour

    Latest articles

    New guides most weeks. Each one is written from a finished install and updated when readers find a better way.

    How to pull a vacuum on a mini split

    Step 5 of the install. 9 min read. Updated November 2026.

    Air and moisture are the two things a refrigerant circuit can't live with. Air raises pressures and wastes capacity. Moisture mixes with the oil and slowly eats the compressor from the inside. Pulling a vacuum removes both before the refrigerant is released from the outdoor unit.

    If your system came with sealed, pre-charged quick-connect lines, the factory already did this and you can skip to startup. For standard flare connections, this step is not optional.

    What you need

    A two-stage vacuum pump, a digital micron gauge, a manifold or a pair of vacuum-rated hoses, a valve core removal tool, and the service port adapter that fits your unit. A manifold's analog needle can't tell you whether you reached a deep vacuum. The micron gauge can.

    The steps

    1. Pressure test first. With the service valves still closed, charge the line set with dry nitrogen to the test pressure in your manual and brush every flare with leak solution. Wait at least 15 minutes. If the pressure holds, release the nitrogen slowly.
    2. Connect the pump to the service port with the shortest, widest hose you have. Put the micron gauge at the port, as far from the pump as you can, so it reads the system and not the hose.
    3. Start the pump and open its valve. The reading falls fast at first, then slows. On a typical 25 ft line set, expect 15 to 30 minutes.
    4. Keep going until the gauge reads 500 microns or lower. In cold or damp weather it takes longer, because water boils off slowly.
    5. Close the valve to the pump, then switch the pump off. Watch the gauge for 10 minutes.
    6. Read the result. Holding under about 1,000 microns means dry and tight. A slow climb that levels off means moisture is still boiling out, so run the pump again. A climb that never stops means a leak, so go back to the flares.
    7. Disconnect, cap the port, and move on to releasing the charge.

    Don't open the service valves early. Once refrigerant is in the lines you can't pull a vacuum again without recovering it, and that job belongs to a licensed technician.

    Common mistakes

    Old pump oil is the usual reason a vacuum stalls around 1,500 microns. Change it before every job; it costs a few dollars. The second is trusting time instead of the gauge. "I ran it for an hour" tells you nothing about what is left inside. The third is skipping the hold test because the number looked good while the pump was running.

    Next: release the charge and start it up

    Sizing helper

    A first estimate for one room or open area. It uses rule-of-thumb figures per square foot for each climate, so treat the answer as a starting point and confirm with a room-by-room load calculation before you buy.

    Insulation
    11,250 BTU/h

    Tool list

    Tick off what you already own. Your list is saved in this browser.

    0 of 14 on hand

    One guide a week, by email